Gas Boilers - Trinity Ti
GENERAL TRINITY DOWNLOADS
Trinity Ti Installation Manual - Revised January 2010
Trinity T Series 6-1-04.pdf
Instructions d'installation et d'entretien
Sales Literature
TRINITY TECHNICAL AND SERVICE DOWNLOADS
Trinity Ti T2.0 Trouble Shooting Flow Chart
Trinity T T1.0 to T2.0 Trouble Shooting Flow Chart
Procedure for Cleaning
Cleaning Plate Heat Exchanger
Brazed Plate Hx Head Loss Curves
T150 Head Loss Curves
T200 Head Loss Curves
T400 Head Loss Curves
TOP TEN ADVANTAGES OF THE TRINITY
- Available in both Natural Gas and Propane versions with a
modulation system that eliminates additional models
- State-of-the-art sealed modulation combustion system with hot
- surface ignition
- Patented 316L stainless condensing heat exchanger provides ultimate efficiencies
- All connections are conveniently located for ease of installation.
- Wall mount configuration saves valuable floor space
- Vents easily with conventional ABS, PVC or CPVC plastic piping
- The TRINITY has industry-leading modulation rates, which
significantly increases comfort while reducing cycling and fuel
consumption
- The distinctive casing design reduces costly standby losses, while virtually eliminating combustion noises
- High-capacity plate heat exchanger on combination models provides ample domestic hot water
- The TRINITY is certified, designed and rated to strict CSA, AGA, ASME and CSAus codes
GENERAL SPECIFICATIONS:
| |
Ti100 |
Ti150 |
Ti200 |
Ti400 |
| Size (D x W x L) |
14" x 15.5" x 22" |
14" x 15.5" x 22" |
17" x 15.5" x 22" |
23.5" x 21" x 36" |
| Weight |
80 lbs. |
80 lbs. |
110 lbs. |
205 lbs. |
| Max. Pressure |
30 PSI |
30 PSI |
30 PSI |
145 PSI |
| Gas Type |
Natural, Propane |
Natural, Propane |
Natural, Propane |
Natural, Propane |
| Max. Vent |
105' equivalen |
105' equivalent |
105' equivalent |
4"-30, 6"-65 eqv. |
| Gas Connection Size |
1/2" NPT |
1/2" NPT |
1/2" NPT |
1/2" NPT |
| Max. Supply Water |
200°F |
200°F |
200°F |
200°F |
| Min. Return Water |
40°F |
40°F |
40°F |
40°F |
| Oxygen Tube Barrier |
Required |
Required |
Required |
Required |
| Certification |
CSA, AGA, CSAus, *ASME |
CSA, AGA, CSAus, *ASME |
CSA, AGA, CSAus, *ASME |
CSA, AGA, CSAus, *ASME |
HEATING SPECIFICATIONS:
| |
Ti100 |
Ti150 |
Ti200 |
Ti400 |
| BTU Input x 1000 |
15-100 |
25-150 |
25-200 |
75-399 |
| BTU Output x 1000 |
14-95 |
23-142 |
23-190 |
71-379 |
| S.S Efficiency |
98% |
98% |
97% |
96% |
| AFUE |
95.1% |
95.1% |
95.1% |
95.1% |
| Head Loss @ GPM |
12' @ 8 |
12' @ 8 |
13' @ 10 |
9' @ 20 |
| Supply-Return |
3/4" NPT |
3/4" NPT |
1" on H, 3/4" on C Models |
1 1/4" NPT |
| Boiler Modulation Ratio |
6.6:1 |
6:1 |
8:1 |
5.3:1 |
| Flow Switch |
Optional |
Optional |
Optional |
Installed |
DOMESTIC HOT WATER:
(Combi Version)
| |
Ti150 |
Ti200 |
| Supply-Return |
3/4" NPT Outlet 1/2" Inlet |
| DHW Pressure Drop |
1 PSI |
| Head Loss @ GPM |
15' @ 8 |
18" @ 10 |
| Temperature Regulation |
Electronic Modulation |
| D.H.W. Outputs at |
4.0 @ 110°F |
5.5 @ 110°F |
| 45° Inlet Water |
3.5 @ 120°F |
4.8 @ 120°F |
| (GPM @ Water °F) |
3.1 @ 130°F |
4.5 @ 130°F |
|